StacksVerified U.S. regulatory reference

40 CFR Part 63, Table 28

Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov

Deck construction | Typical deck seam length factor

Continuous sheet construction b: |

5-feet wide sheets0.2 c
6-feet wide sheets0.17
7-feet wide sheets0.14

Panel construction d: |

5 × 7.5 feet rectangular0.33
5 × 12 feet rectangular0.28

a Deck seam loss applies to bolted decks only. Units for SD are feet per square feet.

b SD = 1/W, where W = sheet width (feet).

c If no specific information is available, these factors can be assumed to represent the most common bolted decks currently in use.

d SD = (L + W)/LW, where W = panel width (feet), and L = panel length (feet).